DESCRIPTION
Wire ropes with fiber core for traction elevators are used as governor ropes because it has high tensile strength, very good bend fatigue and elongation properties. The most frequently used elevator ropes have 6 strand wire rope, 8 Strand wire rope and 9 strand wire ropes. These elevator ropes normally be electric galvanized for corrosion resistance.
Unlike regular wire ropes for other application, elevator wire ropes require much small dimensional tolerance, high quality material and lubrication during stranding to meet its tough safety requirements.
8 strand steel wire ropes are one of the most used wire rope for elevator. Fiber core constructed 8 strands wire ropes have good bend fatigue contributed by the small wires, good elongation and better contact on drum and sheaves. Steel core constructed 8 strands wire ropes have the advantages of very good bend fatigue, super elongation, better crush resistance and better contact on drum and sheaves.
SURFACE FINISH
We provide bright elevator wire ropes and galvanized elevator wire ropes.
STRANDS CONSTRUCTION
Seale Strand: It has larger wires for outer layer and smaller wires for inner wires. Wire ropes with this construction has very good flexibility.
Warrington Strand: This strand is constructed with alternative arrangement of larger wires and smaller wires for outer layer. This strand constructed wire rope has better abrasion resistance.
Filler Strand: Arranged with smaller wires between the outer layer and inner layer to fill the space, this kind of strand has better bend fatigue and better contact with drums and sheaves.
PACKING
■ Certain meters on one polywood reel.
■ Each reel wrapped by moisture proof woven bag.
■ Certain reels stack on one pallet or in one wooden case.

CONSTRUCTION: 8X19S(9-9-1)+FC,8X25F(12-6F-6-1)+FC, 8X19W(6+6-6-1)+FC

APPLICATIONS
Natural fiber core: Suspension ropes for elevator speed <=2m/s, building height <=60m. Suspension ropes for low-rise, low-speed, low-duty elevators. Or suspension ropes for elevator speed >2m/s and <2.5m/s, building height <=60m, suspension ropes for high-rise, high-speed elevators.
Macromoledar polymer core: Suspension ropes for elevator speed >2m/s, and <=2.5m/s, building height <=60m, suspension ropes for high-rise, high-speed elevators
Synthetic fiber core: Governor ropes
Nominal Diameter mm | Approx weight | Minimum Breaking Strength (kN) | ||||||
kg/100m | Double Strength | Single Strengh | ||||||
1320/1620N/mm2 | 1320/1770N/mm2 | 1370/1770N/mm2 | 1570/1770N/mm2 1620/1770N/mm2 | 1570N/mm2 | 1620N/mm2 | 1770N/mm2 | ||
8 | 21.8 | 26.5 | 26.5 | 28.1 | 30.8 | 29.4 | 30.4 | 33.2 |
9 | 27.5 | 33.5 | 33.5 | 35.6 | 38.9 | 37.3 | 38.4 | 42 |
9.5 | 30.7 | 37.3 | 37.3 | 39.7 | 43.6 | 41.5 | 42.8 | 46.8 |
10 | 34 | 41.3 | 41.3 | 44 | 48.1 | 46 | 47.5 | 51.9 |
11 | 41.1 | 50 | 50 | 53.2 | 58.1 | 55.7 | 57.4 | 62.8 |
12 | 49 | 59.5 | 59.5 | 63.3 | 69.2 | 66.2 | 68.4 | 74.7 |
12.7 | 54.8 | 66.6 | 66.6 | 70.9 | 77.5 | 74.2 | 76.5 | 83.6 |
13 | 57.5 | 69.8 | 69.8 | 74.3 | 81.2 | 77.7 | 80.2 | 87.6 |
14 | 66.6 | 81 | 81 | 86.1 | 94.2 | 90.2 | 93 | 102 |
14.3 | 69.5 | 84.5 | 84.5 | 89.9 | 98.3 | 91.1 | 97.1 | 106 |
15 | 76.5 | 93 | 93 | 98.9 | 108 | 104 | 107 | 117 |
16 | 87 | 106 | 106 | 113 | 123 | 118 | 122 | 133 |
17.5 | 104 | 127 | 127 | 135 | 147 | 141 | 145 | 159 |
18 | 110 | 134 | 134 | 142 | 156 | 149 | 154 | 168 |
19 | 123 | 149 | 149 | 159 | 173 | 166 | 171 | 187 |
20 | 136 | 165 | 165 | 176 | 192 | 184 | 190 | 207 |
20.6 | 144 | 175 | 175 | 187 | 204 | 195 | 201 | 220 |
22 | 165 | 200 | 200 | 213 | 233 | 223 | 230 | 251 |
CONSTRUCTION: 8X19S(9-9-1)+IWRC,8X25F(12-6F-6-1)+IWRC, 8X19W(6+6-6-1)+IWRC

Suspension ropes for elevator speed <4m/s, building height <=100m. Suspension ropes for high-rise, high-speed elevators.
Nominal Diameter mm | Approx weight | Minimum Breaking Strength (kN) | ||||||
kg/100m | Double Strength | Single Strengh | ||||||
1320/1620N/mm2 | 1320/1770N/mm2 | 1370/1770N/mm2 | 1570/1770N/mm2 1620/1770N/mm2 | 1570N/mm2 | 1620N/mm2 | 1770N/mm2 | ||
8 | 26 | 33.6 | 33.6 | 35.2 | 37.4 | 35.2 | 36.3 | 39.6 |
9 | 33 | 42.5 | 42.5 | 44.5 | 47.3 | 44.5 | 45.9 | 50.2 |
9.5 | 36.7 | 47.4 | 47.4 | 49.6 | 52.8 | 49.6 | 51.2 | 55.9 |
10 | 40.7 | 52.5 | 52.5 | 55 | 58.5 | 55 | 56.7 | 62 |
11 | 49.2 | 66.5 | 66.5 | 66.5 | 70.7 | 66.5 | 68.6 | 75 |
12 | 58.6 | 75.6 | 75.6 | 79.1 | 84.2 | 79.1 | 81.6 | 89.2 |
12.7 | 65.6 | 84.7 | 84.7 | 88.6 | 94.3 | 88.6 | 91.5 | 99.9 |
13 | 68.8 | 88.7 | 88.7 | 92.9 | 98.8 | 92.9 | 95.8 | 105 |
14 | 79.8 | 103 | 103 | 108 | 115 | 108 | 111 | 121 |
14.3 | 83.2 | 107 | 107 | 112 | 120 | 112 | 116 | 127 |
15 | 91.6 | 118 | 118 | 124 | 132 | 124 | 128 | 139 |
16 | 104 | 134 | 134 | 141 | 150 | 141 | 145 | 159 |
17.5 | 125 | 161 | 161 | 168 | 179 | 168 | 174 | 190 |
18 | 132 | 170 | 170 | 178 | 189 | 178 | 184 | 201 |
19 | 147 | 190 | 190 | 198 | 211 | 198 | 205 | 224 |
20 | 163 | 210 | 210 | 220 | 234 | 220 | 227 | 248 |
20.6 | 173 | 223 | 223 | 233 | 248 | 233 | 241 | 263 |
22 | 197 | 254 | 254 | 266 | 283 | 266 | 274 | 300 |

Steel Wire Rope automatically closing
USE AND MAINTENANCE
Use and Maintenance Information
Use and maintenance information should include restrictions on use under adverse environmental conditions ( temperature, use in particularly hazardous conditions ), inspections of wire ropes prior to first use (inspection of wire ropes and documentation, wire rope storage, machinery, equipment or devices associated with wire ropes, inspection of the condition of the original components ), unwinding and installation of wire ropes ( ropes supplied in coils, wire ropes supplied in axles, cutting of wire ropes, running-in of new wire ropes ), maintenance of wire ropes (inspection of wire ropes, use of oiling of the steel wire rope ) corresponding content.
temperature
The maximum temperature that the wire rope may reach in use should be considered, and it may cause danger if the ambient temperature of the wire rope in use is underestimated.
The maximum temperature that the fiber strand core or fiber rope core multi-strand steel wire rope system can withstand in use is 100℃. Generally, when the temperature exceeds 60℃, the loss of grease of the wire rope will be accelerated and the service life of the wire rope will be reduced.
Wire rope storage
Handling the wire rope, care should be taken. Neither the coil or the axle is allowed to fall, nor is it allowed to directly insert the wire rope with the metal hook or the fork of the forklift to avoid any accidental damage to the wire rope.
Wire ropes should be stored in a clean, well-ventilated, dry, dust-free and sheltered place. If it cannot be stored indoors, the wire rope should be covered with a waterproof material to prevent moisture from rusting.
The storage and handling methods and protective measures of the steel wire rope shall not cause any accidental damage to the steel wire rope during storage or when moving in and out of the warehouse. Wire ropes are not allowed to be stored in places susceptible to chemical fumes, steam or other corrosive media.
If the wire rope is supplied in an axle package for long-term storage ( especially in a hot environment ), the axle should be rotated regularly to prevent the loss of grease in the rope.
High temperature will affect the performance of the steel wire rope. In extreme cases, the breaking force of the steel wire rope in the original manufacturing state will be greatly reduced, so that it cannot meet the requirements of safe use. Therefore, the steel wire rope should not be stored in places that are easily affected by high temperature.
wire rope must not have any direct contact with the ground, and the placement of the axle should ensure that the bottom of the air circulates.
Hot Tags: galvanized elevator wire ropes with fiber core, China, suppliers, manufacturers, factory, free sample, Grade 80 welded master link assembly, Adjustable chain slings, Grade 8 clevis chain shortenting hooks, Black tempered binder chains, Grade 43 High Test Chains, galvanized wire rope thimble