Drop Forged Wire Rope Clips (JIS Type)

Drop Forged Wire Rope Clips (JIS Type)
Product Introduction:
6x12+7FC and 6x24+7FC are the commercial steel wire rope for fishing purpose. Constructed with drawn galvanized wire strand and a fiber core at the center, this wire rope are mainly used for stay wire, release wire and fishing operations.
Social Share:
Send Inquiry
Description
Technical Parameters

6x12+7FC and 6x24+7FC are the commercial steel wire rope for fishing purpose. Constructed with drawn galvanized wire strand and a fiber core at the center, this wire rope are mainly used for stay wire, release wire and fishing operations.   The two construction rope are always coming with fiber core inside. These ropes are commercial quality wire rope with very competitive prices and be widely used.



Specifications 6x12+7FC

Standard: BS302

Surface finish: Ungalvanized, Electric Galvanized, hot dip galvanized

Tensile strength: 1570 /1770 N/mm2

Total number of strands: 6

Total number of wires: 72

Type of core: Fiber

Outer wires number: 66

Outer strands number: 6

Type of lay: regular lay

Direction of lay: right hand lay


Specifications 6x24+7FC

Standard: BS3068

Surface finish: Ungalvanized, Electric Galvanized, hot dip galvanized

Tensile strength: 1570 /1770 N/mm2

Total number of strands: 6

Total number of wires: 144

Type of core: Fiber

Outer wires number: 138

Outer strands number: 6

Type of lay: regular lay

Direction of lay: right hand lay


Technical Data

Construction

Nominal Diameter

Approx weight

Nominal Tensile Strength

Construction

Nominal Diameter

Approx weight

Nominal Tensile Strength

Minimum Breaking Strength (kN)

Minimum Breaking Strength (kN)

mm

kg/100m

1570N/mm²

1770N/mm²

mm

kg/100m

1570N/mm²

1770N/mm²

6x12+7FC

Carbon steel fishing wire rope 6x12+7FC

 

NF/SF

 

 

6x24+7FC

Commercial Fishing wire rope 6x24+7FC

 

NF/SF

 

 

5

6.28/5.78

8.2

9.25

5

7.95/7.60

11

12.4

6

9.04/8.32

11.8

13.3

8

20.40/19.50

28.1

31.7

7

12.30/11.30

16.1

18.1

9

25.80/24.60

35.6

40.1

8

16.10/14.80

21

23.7

10

31.80/30.40

44

49.6

9

20.30/18.70

26.6

30

11

38.50/36.80

53.2

60

10

25.10/23.10

32.8

37

12

45.80/43.80

63.3

71.4

11

30.40/28.00

39.7

44.8

13

53.70/51.40

74.3

83.8

12

36.10/33.30

47.3

53.3

14

62.30/59.60

86.2

97.1

14

49.20/45.30

64.3

72.5

16

81.40/77.80

113

127

16

64.30/59.10

84

94.7

18

103.00/98.50

142

161

18

81.30/74.80

106

120

20

127/122

176

198

20

100/92.40

131

148

22

154/147

213

240

22

121/112

159

179

24

183/175

253

285

24

145/133

189

213

26

215/206

297

335

26

170/156

222

250

28

249/238

345

389

28

197/181

257

290

30

286/274

396

446

30

226/208

295

333

32

326/311

450

507

32

257/237

336

379

34

368/351

508

573

34

290/267

379

428

36

412/394

570

642

36

325/299

425

479

38

459/439

635

716

38

362/334

474

534

40

509/486

703

793

40

402/370

525

592

42

561/536

775

874

42

442/407

579

652

44

616/589

851

959

44

486/447

635

716

46

673/643

930

1050

46

531/488

694

782

48

733/700

1010

1140


Tips of Safe Use Steel Wire Ropes

1. Care must be taken during rope installation since the rope is not supported when it is unrolled from the reel, until it is properly installed.

2. Care must be taken to unroll and not laterally pull wire rope when pulling it off the reel. Be careful not to get any loops.

3. Wire rope cutting: Both sides of cutting point apart 10-20mm using iron wire to tie up, the tie length is 2-4 times of rope diameter. Use proper tools to cut wire ropes. If such tools are not available and a cutting torch must be used, prevent short circuit occurring between the torch tip and the wire rope. When welding job is performed in the elevator shaft, prevent any debris getting on the wire rope and causes damage.

4. If the wire rope is not straight right off the reel, apply tension to the rope and fix it to proper form.

5. Do not drag ropes over sharp edges, and prevent any dirt and debris sticking on the rope. This will cause damage to the traction groove and rope itself.

6. Ropes must be prevented from rotating during installation since free-hanging ropes will untwist under their own weight.

Check the rope tension after mounting with a suitable device. Make sure all ropes in the same group are evenly tensioned.


Inspection of wire rope

Relevant standards for wire ropes

The daily inspection, regular comprehensive inspection and scrapping of wire ropes shall comply with the following standards or procedures:

"National Standard for Steel Wire Rope for Elevator" GB8903-2005

"Safety Use and Maintenance of Wire Rope" GB-T29086-2016

"Elevator Maintenance Rules" TGST5002-2017

Wire ropes that do not meet specifications or regulations should be replaced immediately.

 

Oiling of wire ropes in use

The grease applied during wire rope manufacturing under normal conditions provides adequate protection against corrosion damage during transport, storage and pre-use; however, for optimum performance and service life, most wire ropes will benefit from the maintenance of grease application. The selection of the type of grease mainly depends on the working conditions and environmental conditions of the wire rope.

If the wire rope is not coated with maintenance grease during use, the performance of the wire rope may be degraded, and in severe cases, it may cause undetectable internal corrosion of the wire rope.

Excessive oiling or the wrong type of grease can cause debris to collect on the surface of the rope, causing wear damage to the rope, sheaves, backup rollers and drums, as well as making it difficult to assess the true condition of the rope for scrap.

 

 

Special case

When certain wire rope of a set of suspension or compensation wire ropes is damaged during the installation or acceptance test before the elevator is put into operation, and if the following conditions are met, a new wire rope is allowed to replace the damaged wire rope:

a) The technical parameters of the wire rope used for replacement shall be consistent with the technical parameters stated in the original complete set of wire rope product quality certificate;

b) The above-mentioned set of wire ropes shall not be shortened from the original equipment;

c) After the new replacement wire rope is installed, the tension inspection should be carried out and necessary adjustments should be made, and the time interval is half a month. The period is not less than two months. If the wire rope cannot maintain a proper tension balance after six months, the complete set of suspension wire ropes should be replaced;

d) Replaced wire ropes should use the same type of method used to secure the ends of other suspended wire ropes;

e) Under the action of tension, the diameter change of the replaced wire rope relative to the original wire rope shall not exceed 0.5% of the nominal diameter.


 

Hot Tags: commercial carbon steel fishing wire ropes, China, suppliers, manufacturers, factory, free sample, Grade 100 Omega Link, Stainless steel round ring, heavy duty tow strap with hooks, Long Shank Dynamo Eye Blots, Aluminum Alloy timing belt pulleys, A type Malleable wire rope clips

Send Inquiry