6x12+7FC and 6x24+7FC are the commercial steel wire rope for fishing purpose. Constructed with drawn galvanized wire strand and a fiber core at the center, this wire rope are mainly used for stay wire, release wire and fishing operations. The two construction rope are always coming with fiber core inside. These ropes are commercial quality wire rope with very competitive prices and be widely used.
Specifications 6x12+7FC
Standard: BS302
Surface finish: Ungalvanized, Electric Galvanized, hot dip galvanized
Tensile strength: 1570 /1770 N/mm2
Total number of strands: 6
Total number of wires: 72
Type of core: Fiber
Outer wires number: 66
Outer strands number: 6
Type of lay: regular lay
Direction of lay: right hand lay
Specifications 6x24+7FC
Standard: BS3068
Surface finish: Ungalvanized, Electric Galvanized, hot dip galvanized
Tensile strength: 1570 /1770 N/mm2
Total number of strands: 6
Total number of wires: 144
Type of core: Fiber
Outer wires number: 138
Outer strands number: 6
Type of lay: regular lay
Direction of lay: right hand lay
Technical Data
Construction | Nominal Diameter | Approx weight | Nominal Tensile Strength | Construction | Nominal Diameter | Approx weight | Nominal Tensile Strength | ||
Minimum Breaking Strength (kN) | Minimum Breaking Strength (kN) | ||||||||
mm | kg/100m | 1570N/mm² | 1770N/mm² | mm | kg/100m | 1570N/mm² | 1770N/mm² | ||
6x12+7FC
|
| NF/SF |
|
| 6x24+7FC
|
| NF/SF |
|
|
5 | 6.28/5.78 | 8.2 | 9.25 | 5 | 7.95/7.60 | 11 | 12.4 | ||
6 | 9.04/8.32 | 11.8 | 13.3 | 8 | 20.40/19.50 | 28.1 | 31.7 | ||
7 | 12.30/11.30 | 16.1 | 18.1 | 9 | 25.80/24.60 | 35.6 | 40.1 | ||
8 | 16.10/14.80 | 21 | 23.7 | 10 | 31.80/30.40 | 44 | 49.6 | ||
9 | 20.30/18.70 | 26.6 | 30 | 11 | 38.50/36.80 | 53.2 | 60 | ||
10 | 25.10/23.10 | 32.8 | 37 | 12 | 45.80/43.80 | 63.3 | 71.4 | ||
11 | 30.40/28.00 | 39.7 | 44.8 | 13 | 53.70/51.40 | 74.3 | 83.8 | ||
12 | 36.10/33.30 | 47.3 | 53.3 | 14 | 62.30/59.60 | 86.2 | 97.1 | ||
14 | 49.20/45.30 | 64.3 | 72.5 | 16 | 81.40/77.80 | 113 | 127 | ||
16 | 64.30/59.10 | 84 | 94.7 | 18 | 103.00/98.50 | 142 | 161 | ||
18 | 81.30/74.80 | 106 | 120 | 20 | 127/122 | 176 | 198 | ||
20 | 100/92.40 | 131 | 148 | 22 | 154/147 | 213 | 240 | ||
22 | 121/112 | 159 | 179 | 24 | 183/175 | 253 | 285 | ||
24 | 145/133 | 189 | 213 | 26 | 215/206 | 297 | 335 | ||
26 | 170/156 | 222 | 250 | 28 | 249/238 | 345 | 389 | ||
28 | 197/181 | 257 | 290 | 30 | 286/274 | 396 | 446 | ||
30 | 226/208 | 295 | 333 | 32 | 326/311 | 450 | 507 | ||
32 | 257/237 | 336 | 379 | 34 | 368/351 | 508 | 573 | ||
34 | 290/267 | 379 | 428 | 36 | 412/394 | 570 | 642 | ||
36 | 325/299 | 425 | 479 | 38 | 459/439 | 635 | 716 | ||
38 | 362/334 | 474 | 534 | 40 | 509/486 | 703 | 793 | ||
40 | 402/370 | 525 | 592 | 42 | 561/536 | 775 | 874 | ||
42 | 442/407 | 579 | 652 | 44 | 616/589 | 851 | 959 | ||
44 | 486/447 | 635 | 716 | 46 | 673/643 | 930 | 1050 | ||
46 | 531/488 | 694 | 782 | 48 | 733/700 | 1010 | 1140 | ||
Tips of Safe Use Steel Wire Ropes
1. Care must be taken during rope installation since the rope is not supported when it is unrolled from the reel, until it is properly installed.
2. Care must be taken to unroll and not laterally pull wire rope when pulling it off the reel. Be careful not to get any loops.
3. Wire rope cutting: Both sides of cutting point apart 10-20mm using iron wire to tie up, the tie length is 2-4 times of rope diameter. Use proper tools to cut wire ropes. If such tools are not available and a cutting torch must be used, prevent short circuit occurring between the torch tip and the wire rope. When welding job is performed in the elevator shaft, prevent any debris getting on the wire rope and causes damage.
4. If the wire rope is not straight right off the reel, apply tension to the rope and fix it to proper form.
5. Do not drag ropes over sharp edges, and prevent any dirt and debris sticking on the rope. This will cause damage to the traction groove and rope itself.
6. Ropes must be prevented from rotating during installation since free-hanging ropes will untwist under their own weight.
Check the rope tension after mounting with a suitable device. Make sure all ropes in the same group are evenly tensioned.
Inspection of wire rope
Relevant standards for wire ropes
The daily inspection, regular comprehensive inspection and scrapping of wire ropes shall comply with the following standards or procedures:
"National Standard for Steel Wire Rope for Elevator" GB8903-2005
"Safety Use and Maintenance of Wire Rope" GB-T29086-2016
"Elevator Maintenance Rules" TGST5002-2017
Wire ropes that do not meet specifications or regulations should be replaced immediately.
Oiling of wire ropes in use
The grease applied during wire rope manufacturing under normal conditions provides adequate protection against corrosion damage during transport, storage and pre-use; however, for optimum performance and service life, most wire ropes will benefit from the maintenance of grease application. The selection of the type of grease mainly depends on the working conditions and environmental conditions of the wire rope.
If the wire rope is not coated with maintenance grease during use, the performance of the wire rope may be degraded, and in severe cases, it may cause undetectable internal corrosion of the wire rope.
Excessive oiling or the wrong type of grease can cause debris to collect on the surface of the rope, causing wear damage to the rope, sheaves, backup rollers and drums, as well as making it difficult to assess the true condition of the rope for scrap.
Special case
When certain wire rope of a set of suspension or compensation wire ropes is damaged during the installation or acceptance test before the elevator is put into operation, and if the following conditions are met, a new wire rope is allowed to replace the damaged wire rope:
a) The technical parameters of the wire rope used for replacement shall be consistent with the technical parameters stated in the original complete set of wire rope product quality certificate;
b) The above-mentioned set of wire ropes shall not be shortened from the original equipment;
c) After the new replacement wire rope is installed, the tension inspection should be carried out and necessary adjustments should be made, and the time interval is half a month. The period is not less than two months. If the wire rope cannot maintain a proper tension balance after six months, the complete set of suspension wire ropes should be replaced;
d) Replaced wire ropes should use the same type of method used to secure the ends of other suspended wire ropes;
e) Under the action of tension, the diameter change of the replaced wire rope relative to the original wire rope shall not exceed 0.5% of the nominal diameter.
Hot Tags: commercial carbon steel fishing wire ropes, China, suppliers, manufacturers, factory, free sample, 6 strand steel wire ropes, A 347 Master link assembly, 2 Tones flat webbing slings, Grade 80 Lifting Eye Bolt, Automatic induction infrared elevator light curtain, Adjustbale lifting chain slings